Hole spacing to a fixed via measured from where it is, with its own drill
A fixed via sits anywhere, not on a cell centre, and may have a bigger drill than the router's via; checking hole spacing between cell centres with one drill let the flight controller's routed 0.2 mm via come 0.19 mm from a hand-placed 0.25 mm one. The board now carries each fixed via's drill (from KiCad's padstack name), and cells are checked against fixed vias exactly.
This commit is contained in:
@@ -117,6 +117,8 @@ class Via(Item):
|
||||
#: layer indices the via's pads occupy, and the largest pad as a box
|
||||
layers: list[int] = field(default_factory=list)
|
||||
shape: object = None
|
||||
#: drill diameter in board units, when the padstack name gives it
|
||||
drill: int = 0
|
||||
|
||||
|
||||
@dataclass
|
||||
|
||||
Reference in New Issue
Block a user