freeroute ignored the DSN's planes (KiCad's zones), so it never knew that
pads in a pour are joined by it. On the rc4 power stage those pads sit
inside "keep router off" areas as well, and every connection to them was
dropped without a word.
- Read (plane <net> <shape>) and put each zone on the board as a
ConductionArea of its net. Zones are not obstacles: KiCad refills them
around other nets' copper.
- The grid groups each net's pads and zone pieces that copper already
joins (a pad in a zone, two zones sharing a pad) and routes only between
groups. A connection may end on a zone by a via inside its copper, or by
a track where tracks are allowed.
- wire_keepout now blocks traces only, as KiCad's "no tracks" rule area
does; via_keepout only vias; keepout both, in the grid and in the exact
verifier.
rc4 power stage, exact engine, resolution 2: 2 unconnected, down from 8
(FreeRouting JAR: 12), no DRC errors.