Autowire guide covers the decision tree, threshold tuning, workflow patterns, and troubleshooting. CLAUDE.md updated to reflect the new autowire/ package and tools/autowire.py.
8.5 KiB
Autowire Guide
This guide explains the autowire_schematic tool, which analyzes unconnected nets in a KiCad schematic and automatically selects the best wiring strategy for each one.
Overview
The autowire tool provides a single-call alternative to manually deciding wire vs label vs power symbol for every net. It:
- Analyzes the schematic's netlist to find unconnected nets
- Classifies each net into an optimal wiring strategy based on distance, fanout, crossings, and net name patterns
- Generates a batch plan compatible with
apply_batch - Optionally applies the wiring in one atomic operation
Existing manual tools (add_wire, connect_pins, add_label, apply_batch) remain available for fine-grained control. Autowire is the "do the obvious thing" option.
Quick Reference
| Task | Example Prompt |
|---|---|
| Preview wiring plan | Autowire my schematic at /path/to/project.kicad_sch |
| Apply wiring | Autowire my schematic at /path/to/project.kicad_sch with dry_run=False |
| Wire specific nets only | Autowire only the SPI nets in my schematic |
| Exclude power nets | Autowire my schematic, excluding GND and VCC |
| Adjust distance threshold | Autowire with direct_wire_max_distance=30 |
How the Decision Tree Works
For each unconnected net, the tool walks through these checks in order:
| Priority | Condition | Strategy | Rationale |
|---|---|---|---|
| 1 | Power net (name matches GND/VCC/+3V3/etc, or pin type is power_in/power_out) |
Power symbol | Standard KiCad convention for power rails |
| 2 | Single-pin net | No-connect flag | Avoids ERC warnings on intentionally unused pins |
| 3 | Cross-sheet net | Global label | Global labels are required for inter-sheet connectivity |
| 4 | High fanout (>5 pins by default) | Global label | Labels scale better than wire stars for many connections |
| 5 | Two-pin net, distance <= 10mm | Direct wire | Short enough that a wire is cleaner than a label |
| 6 | Two-pin net, distance > 50mm | Local label | Too far for a clean wire run |
| 7 | Two-pin net, mid-range with >2 crossings | Local label | Avoids visual clutter from crossing wires |
| 8 | Two-pin net, mid-range with few crossings | Direct wire | Wire is the simplest connection |
| 9 | 3-4 pin net | Local label | Star topology with labels is cleaner than a wire tree |
All thresholds are tunable via tool parameters.
Using Autowire
Dry Run (Preview)
Autowire defaults to dry_run=True — it shows you the plan without touching the schematic:
Autowire my schematic at ~/Projects/KiCad/amplifier/amplifier.kicad_sch
The response includes:
- Strategy summary — counts by method (e.g., 12 direct wires, 8 local labels, 4 power symbols, 2 no-connects)
- Per-net plan — each net's chosen method and the reasoning
- Batch file — the generated JSON written to
.mckicad/autowire_batch.json
Applying the Plan
Once you've reviewed the dry run, apply with:
Autowire my schematic at ~/Projects/KiCad/amplifier/amplifier.kicad_sch with dry_run=False
This calls apply_batch internally, which means you get collision detection, label placement optimization, and power symbol stub generation for free.
Filtering Nets
To wire only specific nets:
Autowire only the MOSI, MISO, and SCK nets in my schematic
To exclude nets you've already wired manually:
Autowire my schematic, excluding USB_D_P and USB_D_N
To exclude entire components (e.g., a connector you want to wire by hand):
Autowire my schematic, excluding refs J1 and J2
Tuning Thresholds
The default thresholds work well for typical schematics, but you can adjust them:
| Parameter | Default | Effect |
|---|---|---|
direct_wire_max_distance |
50.0mm | Pins farther apart than this get labels instead of wires |
crossing_threshold |
2 | More crossings than this triggers label fallback |
high_fanout_threshold |
5 | Nets with more pins than this get global labels |
For dense boards with tight pin spacing:
Autowire my schematic with direct_wire_max_distance=25 and crossing_threshold=1
For sparse layouts where longer wires are acceptable:
Autowire my schematic with direct_wire_max_distance=80
Understanding Results
Strategy Summary
{
"strategy_summary": {
"direct_wire": 12,
"local_label": 8,
"global_label": 3,
"power_symbol": 6,
"no_connect": 2
},
"total_nets_classified": 31,
"nets_skipped": 45
}
- nets_skipped includes already-connected nets plus any you excluded — these aren't counted in the classification total.
Per-Net Plan
Each net entry explains the decision:
{
"net": "SPI_CLK",
"method": "local_label",
"pin_count": 2,
"reason": "long distance (67.3mm > 50.0mm)"
}
The reason field traces which branch of the decision tree was taken, useful for understanding why a particular strategy was chosen.
Batch File
The generated .mckicad/autowire_batch.json uses the same schema as apply_batch. You can inspect it, edit it, and apply it manually if you want to tweak individual connections before committing:
Show me the contents of .mckicad/autowire_batch.json
Crossing Estimation
The crossing estimator checks whether a proposed direct wire between two pins would cross existing wires. It uses axis-aligned segment intersection: a horizontal wire crosses a vertical wire when their X/Y ranges overlap (strict inequality — touching endpoints don't count).
This keeps the schematic visually clean by falling back to labels when wires would create a tangled crossing pattern.
Power Net Detection
Power nets are identified by two methods:
- Name matching — GND, VCC, VDD, VSS, +3V3, +5V, +12V, +1.8V, VBUS, VBAT, and variants (AGND, DGND, PGND, etc.)
- Pin type metadata — if any pin on the net has
pintypeofpower_inorpower_outin the netlist, the net is treated as power regardless of its name
This handles custom power rails that don't follow standard naming conventions.
Tips
Best Practices
- Always dry-run first — review the plan before applying. The default
dry_run=Trueexists for a reason. - Wire critical nets manually — for sensitive analog paths, differential pairs, or impedance-controlled traces, use
add_wireorconnect_pinsdirectly, then let autowire handle the rest. - Use exclude_nets for partially-wired designs — if you've already connected some nets, exclude them to avoid duplicate labels.
- Run ERC after autowiring —
validate_schematicconfirms the wiring is electrically correct.
Workflow
A typical autowire workflow:
- Place all components and set values/footprints
- Wire critical signal paths manually (
connect_pins,add_wire) - Run
autowire_schematicin dry-run to preview - Review the plan — adjust thresholds or exclude specific nets if needed
- Apply with
dry_run=False - Run
validate_schematicto verify - Open in KiCad to visually inspect
Troubleshooting
No Nets Classified
If autowire reports 0 nets classified:
- Check that kicad-cli is available — autowire needs it to export the netlist. Set
KICAD_CLI_PATHif needed. - Verify the schematic has components — an empty schematic has no nets to wire.
- Check if nets are already connected — autowire skips nets that appear in the connectivity graph. Run
analyze_connectivityto see what's already wired.
Wrong Strategy for a Net
If a net gets classified incorrectly:
- Check pin types in the netlist — a pin with
power_intype will force POWER_SYMBOL even if the net name is unusual. Export and inspect the netlist withimport_netlist. - Adjust thresholds — if too many nets get labels when you want wires, increase
direct_wire_max_distance. - Use only_nets/exclude_nets — wire the problematic net manually and exclude it from autowire.
Netlist Export Fails
If the auto-export step fails:
- Provide a pre-exported netlist — use
export_netlistto create one, then pass it asnetlist_path. - Check kicad-cli version — KiCad 9+ is required for the
kicadsexprformat. - Check schematic validity — run
validate_schematicto catch structural issues.
Attribution