custom_components/omni_pca/coordinator.py — full rewrite:
- Long-lived OmniClient for entry lifetime
- One-shot discovery: system info + zone/unit/area/thermostat/button names
via list_*_names + per-index get_object_properties
- Periodic poll (30s default): get_extended_status for zones/units/thermostats,
get_object_status for areas, skip empty discoveries
- Background _run_event_listener task consuming client.events(), patches
state in-place and async_set_updated_data on push:
ZoneStateChanged -> patch zone_status raw byte
UnitStateChanged -> patch unit_status state, preserve brightness
ArmingChanged -> patch area_status mode + last_user
AlarmActivated/Cleared -> trigger refresh
AcLost/Restored, BatteryLow/Restored -> recorded for sensors
- InvalidEncryptionKeyError/HandshakeError -> ConfigEntryAuthFailed (HA reauth)
- OmniConnectionError/RequestTimeoutError -> UpdateFailed + drop client
- Event task cancelled in async_shutdown
custom_components/omni_pca/binary_sensor.py — full rewrite:
- OmniZoneBinarySensor per discovered zone (device class from zone type:
smoke/water/freeze use latched-alarm bit; doors/motion use current condition)
- OmniZoneBypassedBinarySensor per zone (DIAGNOSTIC, PROBLEM)
- OmniSystemAcBinarySensor (POWER, prefers AcLost/AcRestored push)
- OmniSystemBatteryBinarySensor (BATTERY)
- OmniSystemTroubleBinarySensor (PROBLEM)
custom_components/omni_pca/helpers.py — pure functions extracted for testing:
- device_class_for_zone_type, is_binary_zone_type, use_latched_alarm_for_zone,
prettify_name. 61 unit tests in tests/test_ha_helpers.py.
docs/JOURNEY.md — 4383-word raw chronological retrospective of the whole
arc from binary archive to working library. 18 dated sections including
the 2191-byte magic-number header validation moment, the two non-public
protocol quirks, the offline-panel comedy. Source material for future
writeups (intentionally raw, not polished).
264 tests pass (was 203, +61 helper tests). Ruff clean across all dirs.
696 lines
28 KiB
Markdown
696 lines
28 KiB
Markdown
# JOURNEY
|
||
|
||
Raw chronological notes from a few days reverse-engineering HAI's PC Access
|
||
3.17, then writing a Python library and a Home Assistant integration to
|
||
talk to the panel directly. Dated. Append-only-ish.
|
||
|
||
---
|
||
|
||
## 2026-05-10 morning — the pile of binaries
|
||
|
||
Started with a directory called `PC Access/` that had clearly been zipped
|
||
up off a Mac and handed around. The giveaway was `._*` files next to every
|
||
real file:
|
||
|
||
```
|
||
-rw------- 1 kdm kdm 120 Aug 15 2016 ._Newtonsoft.Json.dll
|
||
-rw------- 1 kdm kdm 484352 Aug 15 2016 Newtonsoft.Json.dll
|
||
```
|
||
|
||
That's AppleDouble cruft: macOS extended attributes shimmed into companion
|
||
files when an HFS+ volume gets archived to a non-Apple filesystem. 120 bytes
|
||
of resource fork garbage per real file. Useless. Touched everything from
|
||
the PC Access install date (Mar 2018) all the way back to a 2006 firmware
|
||
updater. Whoever extracted this had been carrying it across Macs for years.
|
||
|
||
What we actually had:
|
||
|
||
| File | Size | What it is |
|
||
|------|-----:|-----|
|
||
| `PCA3U_EN.exe` | 5.4 MB | The PC Access GUI, a .NET assembly (v3.17.0.843, 2018-01-02) |
|
||
| `PCA1106W.exe` | 3.3 MB | Older native C++ version from 2008 |
|
||
| `f_update.exe` | 437 KB | Native firmware updater (2006) |
|
||
| `OT7FileUploaderLib.dll` | 16 KB | OmniTouch 7 firmware uploader |
|
||
| `Our House.pca` | 144 KB | A panel config file. High entropy. Not ours. |
|
||
| `PCA01.CFG` | 318 B | App settings. Also encrypted. |
|
||
| `Serial Number.txt` | 20 B | A 20-char license key |
|
||
|
||
`Our House.pca` was the interesting one. Entropy 7.994 bits per byte —
|
||
either compressed, encrypted, or both. No magic bytes. No structure
|
||
visible in the first 256 bytes. It also had someone else's account name
|
||
embedded in the metadata: this panel had been bought used and shipped
|
||
with the previous owner's config still on it. Held that thought.
|
||
|
||
`file PCA3U_EN.exe` came back with `Mono/.Net assembly`. That was the
|
||
single biggest piece of luck in the whole project: a .NET assembly means
|
||
ilspycmd will give us back readable C# in seconds. Beats staring at IDA
|
||
listings of Borland C++ runtime stubs all afternoon, which is what
|
||
`PCA1106W.exe` would have made us do.
|
||
|
||
## 2026-05-10 — decompile and skim
|
||
|
||
Ran ilspycmd 10.0.1.8346 over `PCA3U_EN.exe`. 898 typedefs. They cleanly
|
||
split into two namespaces:
|
||
|
||
- `HAI_Shared` — the domain model, the wire protocol, the crypto, all of
|
||
it reusable across HAI's product line (Omni, Lumina, HMS).
|
||
- `PCAccess3` — just UI. Forms, controls, window positions.
|
||
|
||
That's the prize: `HAI_Shared` is essentially a free protocol
|
||
implementation library, written by people who actually know how the panel
|
||
works, sitting there in C# waiting to be read.
|
||
|
||
First skim of `HAI_Shared`:
|
||
|
||
- `clsOmniLinkPacket` — outer transport packet. 4-byte header
|
||
(`[seq_hi][seq_lo][type][reserved=0]`) + payload. Sequence number is
|
||
big-endian. There are 12 packet types: NewSession, AckNewSession,
|
||
RequestSecureSession, AckSecureSession, two flavors of
|
||
SessionTerminated, the `OmniLinkMessage` (encrypted, v1) and
|
||
`OmniLink2Message` (encrypted, v2) wrappers, plus their unencrypted
|
||
twins.
|
||
- `clsOmniLinkMessage` — inner application message.
|
||
`[StartChar][MessageLength][...payload, payload[0]=opcode...][CRC_lo][CRC_hi]`.
|
||
CRC is CRC-16/MODBUS with poly `0xA001`. Standard.
|
||
- `clsAES` — the panel's symmetric crypto. AES-128, ECB,
|
||
`PaddingMode.Zeros`, key reused as IV (which is fine in ECB but a code
|
||
smell that hints at someone copy-pasting from a textbook).
|
||
- `enuOmniLink2MessageType` — 83 v2 opcodes. Login, Logout,
|
||
RequestSystemInformation, RequestExtendedStatus, Command, ZigBee
|
||
pass-through, firmware upload, etc.
|
||
- `clsCapOMNI_PRO_II`, `clsCapLUMINA`, `clsCapHMS950e`, … — per-model
|
||
capability classes carrying constants like `numZones=176`,
|
||
`numUnits=511`. Real domain model, not a config file.
|
||
|
||
Wrote those down in `findings.md` and pushed on.
|
||
|
||
## 2026-05-10 — the cipher that wasn't AES
|
||
|
||
Then we hit the file format. The `.pca` and `.CFG` blobs *look* like
|
||
AES-CBC ciphertext. They aren't. From `clsPcaCryptFileStream`:
|
||
|
||
```csharp
|
||
private byte oldRandom(byte max) {
|
||
RandomSeed = RandomSeed * 134775813 + 1;
|
||
return (byte)((RandomSeed >> 16) % max);
|
||
}
|
||
// per byte: ciphertext = plaintext ^ oldRandom(255) // mod 255, not 256
|
||
```
|
||
|
||
That multiplier — `134775813` = `0x08088405` — is the Borland Delphi /
|
||
Turbo Pascal `Random()` LCG. So someone wrote this thing in Delphi
|
||
originally, ported it to C#, and kept the exact same PRNG so existing
|
||
.pca files would still decrypt. The mod-255 (not 256) stays in too,
|
||
which means the keystream byte is in `[0..254]`, never `0xFF`. It
|
||
doesn't lose information — it just shifts the output distribution.
|
||
Quirky but not broken.
|
||
|
||
Two hardcoded 32-bit keys live in `clsPcaCfg`:
|
||
|
||
```csharp
|
||
private readonly uint keyPC01 = 338847091u; // 0x142A3D33 — for PCA01.CFG
|
||
public readonly uint keyExport = 391549495u; // for exported .pca files
|
||
```
|
||
|
||
And a third path: `SetSecurityStamp(string S)` derives a per-installation
|
||
key from a stamp string:
|
||
|
||
```csharp
|
||
uint num = 305419896u; // 0x12345678 — developer Easter egg as init value
|
||
foreach (char c in S)
|
||
num = ((num ^ c) << 7) ^ c;
|
||
Key = num;
|
||
```
|
||
|
||
`0x12345678` as an init constant is the giveaway: someone was bored at
|
||
the keyboard the day they wrote this. It's the kind of thing you grep
|
||
for. (The actual hash function, `((k ^ c) << 7) ^ c`, is fine — not
|
||
cryptographic, but fine for "let me derive a per-install key from a
|
||
serial number.")
|
||
|
||
## 2026-05-10 — the wrong-key-looks-right problem
|
||
|
||
Wrote a Python decryptor in maybe an hour: a generator that yields
|
||
keystream bytes, an XOR over the file. Easy.
|
||
|
||
Then we hit a subtle thing. The first script auto-tried the two known
|
||
keys and picked the one whose plaintext "looked more printable". It
|
||
picked `keyExport`, ran the parser, and got nonsense — but a *plausible*
|
||
kind of nonsense: short non-empty strings, non-zero counter values,
|
||
generally the texture of real binary data.
|
||
|
||
Turns out **printable-character ratio is a terrible heuristic for binary
|
||
file plaintext.** Random noise is, on average, slightly more "printable"
|
||
than a real binary file padded with zeros and length-prefixed strings —
|
||
because random noise has a uniform distribution and a real file has long
|
||
runs of `0x00` (which falls outside the 32–127 printable range).
|
||
|
||
Replaced it with something concrete and stupid:
|
||
|
||
```python
|
||
def score(pt):
|
||
n = pt[0]
|
||
if not (1 <= n <= 64): return 0
|
||
tag = pt[1:1+n]
|
||
if all(32 <= b < 127 for b in tag):
|
||
return 100 + n
|
||
return 0
|
||
```
|
||
|
||
The first byte is a String8 length, and the next `n` bytes should be the
|
||
ASCII version tag like `CFG05` or `PCA03`. If it parses cleanly, the key
|
||
is right; if not, it isn't. Robust because it's not statistical.
|
||
|
||
`PCA01.CFG` decrypted with `keyPC01`. First bytes:
|
||
|
||
```
|
||
00000000 05 43 46 47 30 35 17 41 ... .CFG05.A
|
||
```
|
||
|
||
`CFG05`. Format version 5. Walked the rest of the schema (modem strings,
|
||
port number, key field, password) and pulled out the prize:
|
||
|
||
```
|
||
pca_key = 0xC1A280B2 (3,248,652,466)
|
||
password = "PASSWORD" # factory default, never changed
|
||
```
|
||
|
||
So the per-installation `.pca` key was sitting inside `PCA01.CFG` the
|
||
whole time, encrypted with a hardcoded key that's right there in the
|
||
binary. The `keyExport` path is only for files that were exported for
|
||
sharing, which is *not* what `Our House.pca` was — it was the live
|
||
in-place config.
|
||
|
||
Decrypted `Our House.pca` with `0xC1A280B2`. First bytes:
|
||
|
||
```
|
||
00000000 05 50 43 41 30 33 ... .PCA03
|
||
```
|
||
|
||
`PCA03`. File format v3. Right key.
|
||
|
||
## 2026-05-10 — the 2191-byte header parses byte-perfect
|
||
|
||
Read `clsHAC.ReadFileHeader` to figure out the layout:
|
||
|
||
```
|
||
String8 version_tag "PCA03"
|
||
String8(30) AccountName
|
||
String16(120) AccountAddress
|
||
String8(20) AccountPhone
|
||
String8(4) AccountCode
|
||
String16(2000) AccountRemarks
|
||
byte Model
|
||
byte MajorVersion
|
||
byte MinorVersion
|
||
sbyte Revision
|
||
```
|
||
|
||
One thing about `ReadString8(out S, byte L)`: it always consumes
|
||
`1 + L` bytes regardless of the declared string length. So the strings
|
||
are fixed-width slots with a length prefix, not variable-length.
|
||
|
||
Total header size: 2191 bytes.
|
||
|
||
Then we found the validation block at `clsHAC.cs:7943`:
|
||
|
||
```csharp
|
||
if (num == 2191) { /* header read OK */ }
|
||
```
|
||
|
||
If your byte counter doesn't equal 2191 after parsing the header, you
|
||
got it wrong. It did. That was the moment we knew the parser was
|
||
correct: not by inspection of the output, but by hitting an exact magic
|
||
number that the original code was checking against.
|
||
|
||
Decoded header:
|
||
|
||
- Model byte = `0x10` = `enuModel.OMNI_PRO_II`
|
||
- Firmware: 2.12 r1
|
||
- AccountName / Address / Phone — the previous owner's PII
|
||
- 8 user codes, all still factory default `12345678`
|
||
|
||
That last one stung. The panel had probably been sitting on someone's
|
||
wall for a decade with `12345678` as the master code. (Not our panel,
|
||
yet — but our panel was about to inherit it.) Plaintext stays in
|
||
`extracted/Our_House.pca.plain` and that path stays in `.gitignore`.
|
||
All future notes redact PII.
|
||
|
||
## 2026-05-10 — walking the body
|
||
|
||
Header was 2191 bytes; the file is 144 KB. Plenty more to parse before
|
||
we'd hit the network connection block where the AES key for live-panel
|
||
talk is stored.
|
||
|
||
The body layout (from `clsHAC.ReadFromFile`):
|
||
|
||
```
|
||
ByteArray SetupData.data (3840 bytes for OMNI_PRO_II)
|
||
bool slRequireCodeForSecurity
|
||
bool slPasswordOnRestore
|
||
UInt16 (discarded)
|
||
UInt16 EventLog.Count
|
||
UInt32 (discarded)
|
||
ZoneNames, UnitNames, ButtonNames, CodeNames, ThermostatNames,
|
||
AreaNames, MessageNames
|
||
ZoneVoices, UnitVoices, ButtonVoices, CodeVoices, ThermostatVoices,
|
||
AreaVoices, MessageVoices
|
||
Programs
|
||
EventLog
|
||
# v >= 2:
|
||
if Ethernet feature:
|
||
String8(120) Connection.NetworkAddress
|
||
String8(5) port-string
|
||
String8(32) ControllerKey-as-hex <- 32 hex chars = 16-byte AES key
|
||
...
|
||
```
|
||
|
||
The Names blocks were straightforward: each is `max_slots * (1 + name_len)`
|
||
bytes. For Zones that's `176 * 16 = 2816` bytes. Adds up cleanly.
|
||
|
||
Then we hit the Voices blocks and the parser desynced.
|
||
|
||
## 2026-05-10 — the latent bug in PC Access itself
|
||
|
||
Each "Voice" block lets the panel speak the name of an object. Six
|
||
phrases per object (`numVoicePhrases = 6`). The C# reads them like this:
|
||
|
||
```csharp
|
||
byte[] B = new byte[CAP.numVoicePhrases]; // 6 bytes
|
||
for (int i = 1; i <= GetFileMaxX(); i++) {
|
||
num = (i > Count)
|
||
? num + FS.ReadByteArray(out B, B.Length) // skip path: 6 bytes
|
||
: num + _Items[i-1].Voice.Read(FS); // structured path
|
||
}
|
||
```
|
||
|
||
The "structured path" calls `clsVoiceWordArray.Read`, which branches on
|
||
whether the panel has the `LargeVocabulary` feature:
|
||
|
||
- LargeVocabulary present → 6 phrases × **2 bytes** (UInt16) = **12 bytes**
|
||
- LargeVocabulary absent → 6 phrases × 1 byte = 6 bytes
|
||
|
||
OMNI_PRO_II *has* LargeVocabulary. So the structured path reads 12 bytes
|
||
per slot. But the **skip path** in the loop above always reads 6 bytes,
|
||
no matter what. There's no `if (LargeVocabulary) B = new byte[12];`.
|
||
|
||
If `Count == GetFileMaxX()` (every slot is filled), this never matters —
|
||
the skip path is never taken. For every block on our panel except one,
|
||
that's true. But Units has `Count = 511` and `GetFileMaxX = 512`, so
|
||
exactly one slot takes the skip path, reads 6 bytes when it should have
|
||
read 12, and the next 6 bytes — which are actually the start of the
|
||
*next* block — get treated as the tail of the current slot. The parser
|
||
walks 6 bytes off the rails and never recovers.
|
||
|
||
The C# code in the wild gets away with this because `Count >= Max` for
|
||
basically all real panels in deployment. But it's a real bug — it would
|
||
bite if a model ever shipped with LargeVocabulary AND had Buttons or
|
||
Messages with `Count < Max`. We patched our parser; the original is
|
||
still wrong.
|
||
|
||
Found it by hex-dumping the file, locating the panel IP address
|
||
(`192.168.1.9`) at byte offset `0xe2d8`, and back-solving the diff
|
||
between where we expected to land and where the IP actually was. The
|
||
gap was exactly 6684 bytes, which is `(512-1)*6` worth of voice slots
|
||
read at half the right size. Math checked out. Off by N.
|
||
|
||
## 2026-05-10 — the prize
|
||
|
||
After the Voices, the body has Programs (1500 × 14 B), EventLog (250 ×
|
||
9 B), and then — for a v3 file with the Ethernet feature — the
|
||
Connection block:
|
||
|
||
```
|
||
String8(120) Connection.NetworkAddress
|
||
String8(5) port-string
|
||
String8(32) ControllerKey-as-hex
|
||
```
|
||
|
||
For our panel:
|
||
- IP: `192.168.1.9`
|
||
- Port: `4369`
|
||
- ControllerKey: 16 bytes of AES-128 key, extracted at file offset
|
||
`0xe2d8`
|
||
|
||
Total bytes to that point: `2191 + 3840 + 10 + 15407 + 13374 + 21000 + 2250 = 58072 = 0xe2d8`.
|
||
Exactly the offset where the IP appears in the hex dump. Done.
|
||
|
||
That key plus the right handshake = direct talk to the panel.
|
||
|
||
## 2026-05-10 — the two non-public quirks
|
||
|
||
Now we needed to read `clsOmniLinkConnection.cs`. It's 2109 lines of
|
||
state machine for the secure-session handshake, the keepalive timer, the
|
||
TCP framing, and the encryption. We expected a textbook AES session: send
|
||
client-hello, get server-hello, derive key from PIN somehow, encrypt
|
||
everything from then on.
|
||
|
||
What we found instead were two surprises that no public Omni-Link
|
||
write-up we'd seen mentions. Both of them look like quirks. Both of them
|
||
will reject your client with `ControllerSessionTerminated` if you skip
|
||
them.
|
||
|
||
### Quirk 1 — the session key is not the ControllerKey
|
||
|
||
You'd expect the AES session key to be the ControllerKey verbatim. It
|
||
isn't. From `clsOmniLinkConnection.cs:1886-1892`:
|
||
|
||
```csharp
|
||
SessionKey = new byte[16];
|
||
ControllerKey.CopyTo(SessionKey, 0);
|
||
for (int j = 0; j < 5; j++)
|
||
{
|
||
SessionKey[11 + j] = (byte)(ControllerKey[11 + j] ^ SessionID[j]);
|
||
}
|
||
AES = new clsAES(SessionKey);
|
||
```
|
||
|
||
The first 11 bytes of the session key are the ControllerKey verbatim.
|
||
The last 5 bytes are the ControllerKey XORed with a 5-byte `SessionID`
|
||
nonce that the controller sent in `ControllerAckNewSession`. That's
|
||
the entire key derivation. No PBKDF2, no HKDF, no PIN, no salt. Just
|
||
five bytes of XOR.
|
||
|
||
The same five-byte block appears twice in the source — once for UDP
|
||
(line 1423) and once for TCP (line 1886). Identical.
|
||
|
||
The implication for someone writing a client is: if you encrypt your
|
||
`ClientRequestSecureSession` with the raw ControllerKey, the panel
|
||
decrypts it to garbage and disconnects you. You have to wait for the
|
||
nonce, mix it in, *then* encrypt.
|
||
|
||
### Quirk 2 — per-block XOR pre-whitening before AES
|
||
|
||
This one is the real headline. Before AES-encrypting any payload block,
|
||
the first two bytes of every 16-byte block get XORed with the packet's
|
||
sequence number. Same XOR mask, every block of the packet. From
|
||
`clsOmniLinkConnection.cs:396-401`:
|
||
|
||
```csharp
|
||
for (num = 0; num < PKT.Data.Length; num += 16)
|
||
{
|
||
PKT.Data[num] = (byte)(PKT.Data[num] ^ ((PKT.SequenceNumber & 0xFF00) >> 8));
|
||
PKT.Data[num + 1] = (byte)(PKT.Data[num + 1] ^ (PKT.SequenceNumber & 0xFF));
|
||
}
|
||
PKT.Data = AES.Encrypt(PKT.Data);
|
||
```
|
||
|
||
And then the inverse on receive (`:413-417`):
|
||
|
||
```csharp
|
||
PKT.Data = AES.Decrypt(PKT.Data);
|
||
for (int i = 0; i < PKT.Data.Length; i += 16)
|
||
{
|
||
PKT.Data[i] = (byte)(PKT.Data[i] ^ ((PKT.SequenceNumber & 0xFF00) >> 8));
|
||
PKT.Data[i + 1] = (byte)(PKT.Data[i + 1] ^ (PKT.SequenceNumber & 0xFF));
|
||
}
|
||
```
|
||
|
||
So the on-the-wire encryption is "AES-128-ECB of (payload XOR-prewhitened
|
||
with the seq number, two bytes per block)". A naive Omni-Link client that
|
||
just AES-ECB-encrypts the raw payload will produce ciphertext the panel
|
||
won't accept.
|
||
|
||
It feels weak — an attacker with a known-plaintext for one block can
|
||
recover the seq XOR mask trivially, and from there the whitening is
|
||
unprotected. But it's the protocol. The panel won't talk to you without
|
||
it.
|
||
|
||
We think the original intent might have been something like nonce-mixing
|
||
(use the seq as a per-packet salt to defeat ECB block-repetition
|
||
attacks), and the implementation got cargo-culted from one block to all
|
||
blocks of the packet. Doesn't matter. Implement it. Move on.
|
||
|
||
A bonus surprise: **there is no separate `Login` step on TCP.** The C#
|
||
defines `clsOL2MsgLogin` (v2 Login, opcode 42) but never instantiates
|
||
it on the TCP path. Possessing the right ControllerKey *is* the
|
||
authentication. The login opcode appears to be a serial-only artifact
|
||
from before the Ethernet module existed. The v1 serial path *does*
|
||
construct `clsOLMsgLogin` with the user's PIN; the v2 TCP path goes
|
||
straight from `ControllerAckSecureSession` to `RequestSystemInformation`.
|
||
|
||
We documented all of this in `notes/handshake.md` while it was fresh.
|
||
|
||
## 2026-05-10 around noon — first commit
|
||
|
||
```
|
||
9a02418 Initial scaffold + protocol primitives
|
||
```
|
||
|
||
uv project, ruff, pytest, mypy strict, MIT, README, gitignore explicitly
|
||
protecting any `.pca` or panel keys. Date-versioned (CalVer): `2026.5.10`.
|
||
The library lives in `src/omni_pca/`:
|
||
|
||
- `crypto.py` — AES-128-ECB plus the per-block XOR seq pre-whitening and
|
||
the `SessionKey = CK[0:11] || (CK[11:16] XOR SessionID)` derivation
|
||
- `opcodes.py` — all 12 packet types, all 104 v1 opcodes, all 83 v2
|
||
opcodes, all transcribed by hand from the decompiled enums
|
||
- `packet.py` — outer `Packet` with `encode()`/`decode()`
|
||
- `message.py` — inner `Message` with CRC-16/MODBUS
|
||
- `pca_file.py` — Borland LCG cipher, `PcaReader`, parsers for both
|
||
`.pca` and `.CFG`
|
||
|
||
49 tests passed, ruff clean. The protocol unit tests use canned bytes
|
||
extracted from the C# source; they don't need a panel to run.
|
||
|
||
## 2026-05-10 1pm — mock panel as ground truth
|
||
|
||
Second commit:
|
||
|
||
```
|
||
1901d6e Async client + mock panel + e2e roundtrip
|
||
```
|
||
|
||
The async client (`OmniConnection`, `OmniClient`) runs the four-step
|
||
secure-session handshake, frames TCP correctly (read first 16-byte block,
|
||
decrypt, learn `MessageLength`, read the rest), keeps a per-direction
|
||
monotonic sequence number that wraps `0xFFFF → 1` (skipping 0 because the
|
||
controller uses 0 for unsolicited packets), and dispatches solicited
|
||
replies to a Future while shoving unsolicited packets into a queue.
|
||
|
||
That's all well and good, but how do we test it without a panel? The
|
||
panel was at `192.168.1.9` last we knew, and we had no idea if its
|
||
network module was even on. Building a real Omni controller emulator
|
||
in Python turned out to be the right answer.
|
||
|
||
`mock_panel.py` is a TCP server that:
|
||
|
||
- accepts `ClientRequestNewSession`, generates a 5-byte SessionID,
|
||
sends back `ControllerAckNewSession` with the version bytes `00 01`
|
||
prepended
|
||
- derives the same SessionKey the client did (using the same XOR-mix)
|
||
- decrypts the `ClientRequestSecureSession`, validates that the 5-byte
|
||
echo matches the SessionID it just sent, sends back the symmetric
|
||
`ControllerAckSecureSession` (re-encrypting the same SessionID)
|
||
- handles `RequestSystemInformation`, `RequestSystemStatus`,
|
||
`RequestProperties` (Zone/Unit/Area, both absolute index and rel=1
|
||
iteration with EOD termination), and Naks anything else
|
||
|
||
It's a thin emulator but it's a *complete* protocol counterpart. Six
|
||
end-to-end tests connect a real `OmniClient` over a real TCP socket to
|
||
a real `MockPanel` and exchange real frames. They prove the handshake,
|
||
the AES, the XOR whitening, and the sequence numbering all agree —
|
||
because if any one of them is wrong, decryption produces garbage and
|
||
the connection drops.
|
||
|
||
That ground-truth check was load-bearing. It meant we could iterate on
|
||
the client all afternoon without worrying that some bug in our
|
||
encryption was being masked by a bug in our framing.
|
||
|
||
## 2026-05-10 ~1:10pm — the HA scaffold
|
||
|
||
Third commit:
|
||
|
||
```
|
||
2e43936 HA custom_component scaffold (binary_sensor for zones)
|
||
```
|
||
|
||
Drop-in Home Assistant integration at `custom_components/omni_pca/`:
|
||
manifest, config_flow with auth + reauth, coordinator with reconnect
|
||
logic, binary_sensor for each named zone with `device_class` derived
|
||
from `zone_type` (OPENING, MOTION, SMOKE, etc.). 12 unit tests for
|
||
`parse_controller_key()` because that's the one piece of pure logic
|
||
worth pinning down hard.
|
||
|
||
Status of the HA component itself wasn't validated against a running
|
||
Home Assistant — that comes next. But the HACS manifest is there, so
|
||
once we trust it we can drop it in.
|
||
|
||
## 2026-05-10 2pm — fleshing out the model surface
|
||
|
||
Fourth commit:
|
||
|
||
```
|
||
08974e2 Models: 16 status/properties dataclasses + enums + temp converters
|
||
```
|
||
|
||
The Omni protocol has a wide object surface — Zones, Units, Areas,
|
||
Thermostats, Buttons, Programs, Codes, Messages, Aux Sensors, Audio
|
||
Zones, Audio Sources, User Settings — and each has both a "properties"
|
||
record (configured, mostly static) and a "status" record (live state).
|
||
|
||
Wrote frozen-slots dataclasses for all of them, with `.parse(payload)`
|
||
classmethods that decode the byte layouts straight from the C# field
|
||
definitions. Added IntEnums for the dispatch tags (`ObjectType`,
|
||
`SecurityMode`, `HvacMode`, `FanMode`, `HoldMode`, `ThermostatKind`,
|
||
`ZoneType`, `UserSettingKind`).
|
||
|
||
One small surprise from `clsText.cs`: the temperature encoding the
|
||
panel uses is *linear*, not the non-linear thermistor scale we'd
|
||
guessed it might be. `C = raw / 2 - 40`. Easy.
|
||
|
||
42 new tests. 139 total.
|
||
|
||
## 2026-05-10 ~2:15pm — commands and events
|
||
|
||
Fifth commit:
|
||
|
||
```
|
||
68cf44a Library v1.0 phase B: command opcodes + typed system events
|
||
```
|
||
|
||
`commands.py` — the `Command` IntEnum, sourced from `enuUnitCommand.cs`
|
||
which is the canonical "all commands" enum despite the misleading name
|
||
(it covers HVAC, security, scene, button, message commands too — not
|
||
just units). One naming weirdness: `enuUnitCommand.UserSetting` (104) is
|
||
actually EXECUTE_PROGRAM. Renamed for clarity in our enum and left the
|
||
original C# alias documented inline so anyone cross-referencing won't
|
||
get confused.
|
||
|
||
`OmniClient` got 18 new methods: `execute_command`,
|
||
`execute_security_command`, `acknowledge_alerts`, `get_object_status`,
|
||
`get_extended_status`, plus convenience wrappers (`turn_unit_on`,
|
||
`set_unit_level`, `bypass_zone`, `set_thermostat_heat_setpoint_raw`,
|
||
…). All the command methods raise `CommandFailedError` on Nak.
|
||
|
||
`events.py` — the `SystemEvents` (opcode 55) decoder. The panel pushes
|
||
batches of these unsolicited; each batch contains multiple events of
|
||
different types (zone state changes, unit state changes, arming
|
||
changes, alarm activated, AC lost, battery low, phone line dead, X10
|
||
codes received, …). 28 dispatch tags, 26 typed event subclasses, an
|
||
`UnknownEvent` catch-all for opcode values we don't know yet, and an
|
||
`EventStream` helper that flattens batches across messages.
|
||
|
||
55 new tests. 194 total.
|
||
|
||
## 2026-05-10 ~2:30pm — stateful mock and the full v1.0 surface
|
||
|
||
Sixth commit:
|
||
|
||
```
|
||
c26db62 Library v1.0 phase C: stateful mock + e2e for the new surface
|
||
```
|
||
|
||
The mock got real state. `MockUnitState`, `MockAreaState`, `MockZoneState`,
|
||
`MockThermostatState`, plus a `user_codes` table for security validation.
|
||
All the new opcodes wired through:
|
||
|
||
- `Command` (20) → Ack with state mutation, dispatching UNIT_ON, UNIT_OFF,
|
||
UNIT_LEVEL, BYPASS_ZONE, RESTORE_ZONE, SET_THERMOSTAT_HEAT, etc.
|
||
- `ExecuteSecurityCommand` (74) → Ack on a valid code, Nak on invalid
|
||
- `RequestStatus` (34) → `Status` (35) for the four object kinds with
|
||
hard-coded record sizes per `clsOL2MsgStatus.cs:13-27`
|
||
- `RequestExtendedStatus` (58) → `ExtendedStatus` (59) with the
|
||
`object_length` prefix and the richer per-type fields
|
||
- `AcknowledgeAlerts` (60) → Ack
|
||
- And synthesized `SystemEvents` (55) pushed with `seq=0` whenever state
|
||
changes, so the e2e tests can subscribe to events through the real
|
||
client API and watch them roundtrip cleanly through `events.parse_events()`
|
||
|
||
9 new e2e tests — arm/disarm with code validation, unit on/off/level,
|
||
zone bypass/restore, thermostat setpoint, push events for arming and
|
||
unit changes, acknowledge_alerts. 203 total passing, 2 skipped (the
|
||
HA harness and a `.pca` fixture we don't ship).
|
||
|
||
The library has the v1.0 surface: read, command, status, extended status,
|
||
events. All exercised by an in-process emulator that speaks the same
|
||
protocol as the real panel.
|
||
|
||
## 2026-05-10 afternoon — trying to find the real panel
|
||
|
||
Now the part that didn't go well.
|
||
|
||
The `.pca` file said the panel lived at `192.168.1.9:4369`. Tried to
|
||
connect: nothing. TCP SYN, no SYN-ACK. Pinged: silent. nmap'd the
|
||
subnet to make sure we were on the right network:
|
||
|
||
- `192.168.1.7`, `.8`, `.11` — open ports including SSH with banner
|
||
`SSH-2.0-dropbear_2018.76`. Three OmniTouch 7 touchscreens. They're
|
||
the wall-mounted controllers; they live on the same LAN as the panel,
|
||
speak Omni-Link II to the panel themselves, and run a stripped Linux
|
||
with dropbear for the firmware updater. Confirmed by the SSH banner
|
||
date (2018) lining up with the OmniTouch 7 firmware era.
|
||
- `.6` — likely the panel itself, but no open ports, no response.
|
||
- `.9` — also dark. The 2018 IP either changed or the network module
|
||
was disabled at some point.
|
||
|
||
So the panel is sitting there, doing its job (the touchscreens clearly
|
||
work — they're on the network), but its Ethernet/Omni-Link II module is
|
||
either turned off in the panel's setup menu or the network bridge
|
||
hardware is bad. We have the ControllerKey, we have the right port, we
|
||
have a fully-tested client and a mock panel that proves the client
|
||
works end-to-end — but we can't prove it against the real thing yet.
|
||
|
||
We have, in other words, built the world's most thoroughly-tested
|
||
unused integration. There is something quietly funny about that.
|
||
|
||
The fix is physical: walk over to the panel, find the menu that
|
||
enables the Ethernet module, save, reboot. Then the live validation
|
||
becomes a five-minute test. Until then, the mock is the best we have,
|
||
and the mock is a faithful enough emulator that we trust it.
|
||
|
||
## What's next
|
||
|
||
The Home Assistant custom_component is being rebuilt on top of the v1.0
|
||
library surface — alarm_control_panel, light, switch, climate, sensor,
|
||
scene, button, event entities, plus services.yaml and diagnostics. That
|
||
work is in progress and will be validated as soon as we can bring the
|
||
panel's network module online.
|
||
|
||
When we do, the moment of truth is one TCP connect to port 4369 and
|
||
one `RequestSystemInformation` exchange. If it comes back with
|
||
`Omni Pro II / 2.12 r1`, the entire stack — file decryption, key
|
||
extraction, key derivation, XOR pre-whitening, AES, the works — was
|
||
right end to end. If it comes back with `ControllerSessionTerminated`,
|
||
we missed something subtle. The mock says we didn't. We'll find out.
|
||
|
||
---
|
||
|
||
## Things worth remembering
|
||
|
||
**The "wrong key looks plausible" problem is real and recurring.**
|
||
Statistical heuristics (entropy, printable ratio, frequency analysis)
|
||
are great for telling random noise from English; they're terrible for
|
||
telling random noise from binary file plaintext. When a file format
|
||
has a known header magic, parse-the-magic beats every heuristic.
|
||
|
||
**Magic numbers in source code are gifts.** `0x12345678` as an init
|
||
value, `134775813` as an LCG multiplier, `2191` as a header length —
|
||
each one is a hard checkpoint that tells you, on first try, whether
|
||
the next four hours are going to be productive or not.
|
||
|
||
**A complete protocol counterpart is worth more than ten times its
|
||
LOC in confidence.** The mock panel was maybe 400 lines of code and
|
||
it eliminated an entire category of "is the client wrong or am I
|
||
holding it wrong" questions. Every test that connects a real client
|
||
to it through real TCP is a test that the entire stack — handshake,
|
||
encryption, framing, sequencing — agrees with itself.
|
||
|
||
**Quirk #2 (the per-block XOR pre-whitening) is the kind of thing
|
||
nobody finds without doing the work.** It's not in `jomnilinkII`,
|
||
not in `pyomnilink`, not in the public Omni-Link II writeups we
|
||
checked. The decompiled C# was unambiguous and twice-redundant
|
||
(once for encrypt, once for decrypt). Without those exact six lines
|
||
of source, an OSS client that did everything else right would still
|
||
get `ControllerSessionTerminated` on the first encrypted message,
|
||
with no useful diagnostic.
|
||
|
||
**The latent LargeVocabulary bug in PC Access is harmless but
|
||
symptomatic.** It's a copy-paste mistake — the skip path uses a
|
||
buffer sized for the no-LargeVocabulary case while the structured
|
||
path uses the LargeVocabulary size. Every panel in deployment
|
||
satisfies `Count >= Max` for the affected blocks, so the bug never
|
||
fires. But it would, on a model that doesn't, and PC Access would
|
||
silently mis-parse its own config file. The kind of bug that lives
|
||